Connectors and terminals: the number one field failure

A perfect circuit is no use if a connector falls out or burns. Current rating, pitch, locking, and preventing polarity mistakes.

GROUND EMBEDDED · NOTEPractical Components 05Connectors and terminalsVCC 3.3V10kΩButtonMCUGPIOHIGH when released

What to look at when choosing

Current and voltagePin count and pitchLockingstays in under vibrationKeyingcannot go in backwards
The order for choosing a connector.
Item Reason
Current rating (per pin) Contact-resistance heating melts it
Pitch 2.54 mm, 2.0 mm, 1.25 mm and so on. The smaller, the lower the rating
Locking With vibration, a latch is essential
Mating cycles Life, if it is plugged and unplugged often
Polarity key A shape that cannot be inserted backwards

Commonly used families

  • Pin headers: prototypes, debug ports. Weak against vibration
  • JST (XH, PH, GH): small devices, batteries, sensor cables
  • Molex Micro-Fit: power at a few amps
  • XT60, XT90: high-current batteries for drones and electric scooters
  • Automotive (TE, Yazaki): waterproof, vibration-resistant

Design habits

  • Use power pins at 50% of their rating or less; if that is not enough, parallel several pins
  • When power and signals share a connector, place ground pins next to the signals
  • Two connectors of the same shape on one board invite swapped plugs. Make the pin count or colour different.
  • Put a TVS and a filter next to the connector to stop incoming noise at the entrance.