The voltage range of lithium batteries, balancing cells in series, and protection against overcharge, over-discharge and overcurrent. The basics when designing a battery device.

GROUND EMBEDDED · NOTEPower Electronics 06Batteries and BMSNSABC

Lithium-ion cell

Item Value (typical NMC)
Nominal voltage 3.6 to 3.7 V
Fully charged 4.2 V
Discharge lower limit 2.5 to 3.0 V
Charging Constant current (CC) → constant voltage (CV) once 4.2 V is reached

Charging above 4.2 V or discharging below the lower limit shortens life sharply and becomes dangerous. Ten 18650 cells in series (10S) make a pack of 36 V nominal and 42 V fully charged.

What a BMS does

Cell voltageovercharge · over-dischargeCurrentovercurrent · shortTemperatureCell balancingCut off on a fault
What a BMS watches.
  • Cell voltage monitoring: measures the voltage of each cell in the series string
  • Protection: cuts off with MOSFETs on overcharge, over-discharge, overcurrent, short circuit or overtemperature
  • Cell balancing: cells differ slightly in capacity, so the highest cell reaches 4.2 V first. The high cell is discharged a little through a resistor (passive), or energy is moved between cells (active), to even them out.
  • State-of-charge (SOC) estimation: current integration (coulomb counting) + voltage correction, Kalman filter

Design cautions

  • The short-circuit current of a single cell is tens to hundreds of amps. Size the fuse and the wiring for this current.
  • When a motor decelerates, regenerated current flows into the battery. Regenerating at full charge can trip overcharge protection.
  • Temperature: no charging below 0 °C (lithium plating), and limited discharge at high temperature